Difference between revisions of "IntegrationDaq 240628"
From Moller Wiki
(→Minutes) |
|||
(2 intermediate revisions by one other user not shown) | |||
Line 12: | Line 12: | ||
* Activity updates | * Activity updates | ||
** Zhongling will report on [https://logbooks.jlab.org/entry/4311500 V2495 FPGA update] | ** Zhongling will report on [https://logbooks.jlab.org/entry/4311500 V2495 FPGA update] | ||
− | ** Bryan will report on [ | + | ** Bryan will report on [https://userweb.jlab.org/~moffit/meetings/DAQ/forWilliam/2024-Jun-28-MOLLER_Integrating_DAQ.pdf MOLLERADC Trigger Sync] |
* General discussion | * General discussion | ||
Line 23: | Line 23: | ||
Recording at zoomgov: | Recording at zoomgov: | ||
− | Participants: | + | Participants: B. Moffit, W. Gu, P. King, R. Michaels, R. Conaway, A. Sen, K. Dehmelt, J. Pan, Z. Ji, B. Shaw, B. Blaikie, S. Kundu, M. Gericke, C. Ghosh, D. Bishop, S. Chatterjee, H. Liu |
+ | |||
+ | * I have made edits in the specification document, and I think that it is basically complete from my perspective. | ||
+ | ** Michael doesn't think he needs to add anything else to it | ||
+ | * Bryan & William | ||
+ | ** He has the two two MOLLER-ADCs connected to a VME-TI | ||
+ | ** He's monitoring the VME-TI trigger out, and William has a modified the ADC firmware to send the trigger signal out to the back panel output | ||
+ | ** They can walk the trigger as seen by the ADC by up to ~1 us, and they see the trigger time move appropriately | ||
+ | ** There are several firmware updates in the TI module | ||
+ | ** They can read out the TI trigger bank | ||
+ | ** He has a zmq port for the TI registers | ||
+ | ** There are still a few issues that Bryan and William that are still tracking down, that are inconsistencies in the firmware response. | ||
+ | ** These tests show the hardware is working and the signals are getting where they need to on the board | ||
+ | * Daryl thinks that with Bryan and William's recent work he'd be comfortable to make the final layout updates, and then we'd be ready to send out the production order | ||
+ | ** Daryl will make the updates within the next few weeks; Michael guesses that the production order would then go out around the end of July | ||
+ | * Michael asks if one of the two ADC modules could be taken up to W&M in the early fall to be used for the detector tests | ||
+ | ** Bryan thinks that the remainder of the synchronization tests could be finished in a month or two | ||
+ | *** After that point, most of the development would be to build up experience with the board to get ready for larger-scale testing | ||
+ | ** Maybe it is better to get a third ADC for use at W&M. TRIUMF has two and will send one of them to Michael; they'll use it for tests at Manitoba for the rest of the summer and then bring it to W&M in the fall. | ||
+ | * Digital BCM readout through a V2495 | ||
+ | ** They have verified that the V2495 can decode the serial data from the digital receivers | ||
+ | ** They have set up an internal test where the V2495 sends a 32-bit-wide parallel data stream over a parallel cable to the decoder module. | ||
+ | *** This is fast enough data transfer to allow us to resolve the 10us spin flip | ||
+ | ** Testing of doing integration using an external gate | ||
+ | *** Sending two bursts of Manchester data with different time spacings. | ||
+ | **** With the serial transmission, the two bursts merge and the initial data burst is lost. (Note that 28 bits should take ~28us to be transmitted with the current transceiver speed on the digital receiver). | ||
+ | **** Either getting a higher data rate transceiver or parallel data transfer from the digital receiver would be possible to get to the 10us spin flip resolution | ||
+ | ** Bob had talked with Chad Seaton, and the instrumentation group thinks that a faster transceiver would be possible | ||
+ | * We will not have the counting DAQ meeting on 5 July; the next DAQ meeting will be the integration DAQ meeting on 12 July |
Latest revision as of 17:54, 28 June 2024
Back to Main Page >> Data Acquisition Meetings >> Integrating mode DAQ meetings
previous meeting << >> following meeting
Meeting information
Meeting time: 1:00pm Eastern Zoom connection information is sent out by email; please reach out to Paul if you don't have the current link.
Agenda
- Activity updates
- Zhongling will report on V2495 FPGA update
- Bryan will report on MOLLERADC Trigger Sync
- General discussion
Open Issues to be followed up later
- Discussions with M. Pitt & J. Musson to understand the beam monitor signals we'll be getting
- Draft timing diagram: DocDB 790
- Michael, Bob, Brynne, and Paul should put together a list of the integrator running modes we would like to have available
Minutes
Recording at zoomgov:
Participants: B. Moffit, W. Gu, P. King, R. Michaels, R. Conaway, A. Sen, K. Dehmelt, J. Pan, Z. Ji, B. Shaw, B. Blaikie, S. Kundu, M. Gericke, C. Ghosh, D. Bishop, S. Chatterjee, H. Liu
- I have made edits in the specification document, and I think that it is basically complete from my perspective.
- Michael doesn't think he needs to add anything else to it
- Bryan & William
- He has the two two MOLLER-ADCs connected to a VME-TI
- He's monitoring the VME-TI trigger out, and William has a modified the ADC firmware to send the trigger signal out to the back panel output
- They can walk the trigger as seen by the ADC by up to ~1 us, and they see the trigger time move appropriately
- There are several firmware updates in the TI module
- They can read out the TI trigger bank
- He has a zmq port for the TI registers
- There are still a few issues that Bryan and William that are still tracking down, that are inconsistencies in the firmware response.
- These tests show the hardware is working and the signals are getting where they need to on the board
- Daryl thinks that with Bryan and William's recent work he'd be comfortable to make the final layout updates, and then we'd be ready to send out the production order
- Daryl will make the updates within the next few weeks; Michael guesses that the production order would then go out around the end of July
- Michael asks if one of the two ADC modules could be taken up to W&M in the early fall to be used for the detector tests
- Bryan thinks that the remainder of the synchronization tests could be finished in a month or two
- After that point, most of the development would be to build up experience with the board to get ready for larger-scale testing
- Maybe it is better to get a third ADC for use at W&M. TRIUMF has two and will send one of them to Michael; they'll use it for tests at Manitoba for the rest of the summer and then bring it to W&M in the fall.
- Bryan thinks that the remainder of the synchronization tests could be finished in a month or two
- Digital BCM readout through a V2495
- They have verified that the V2495 can decode the serial data from the digital receivers
- They have set up an internal test where the V2495 sends a 32-bit-wide parallel data stream over a parallel cable to the decoder module.
- This is fast enough data transfer to allow us to resolve the 10us spin flip
- Testing of doing integration using an external gate
- Sending two bursts of Manchester data with different time spacings.
- With the serial transmission, the two bursts merge and the initial data burst is lost. (Note that 28 bits should take ~28us to be transmitted with the current transceiver speed on the digital receiver).
- Either getting a higher data rate transceiver or parallel data transfer from the digital receiver would be possible to get to the 10us spin flip resolution
- Sending two bursts of Manchester data with different time spacings.
- Bob had talked with Chad Seaton, and the instrumentation group thinks that a faster transceiver would be possible
- We will not have the counting DAQ meeting on 5 July; the next DAQ meeting will be the integration DAQ meeting on 12 July