Difference between revisions of "Simulation Meeting March 19 2020 10AM ET"
From Moller Wiki
(→Minutes) |
(→Minutes) |
||
Line 21: | Line 21: | ||
** test simulations on blocks of Pb with electrons, neutrons, gammas | ** test simulations on blocks of Pb with electrons, neutrons, gammas | ||
** implementing beampipe drawings from Dave Kashy | ** implementing beampipe drawings from Dave Kashy | ||
− | + | * Sakib: | |
+ | ** sources of photon background from real shielding | ||
+ | *** full geo, full geo - shower max shielding, full geo - shower max and shielding | ||
+ | **** lead shielding causes 50 GHz of 1-10 MeV photon background | ||
+ | **** showermax itself causes 40 GHz | ||
+ | **** lead collars causes 80 GHz | ||
+ | *** still looking for source of 100 GHz | ||
<br><br> Return to [[Simulation_Meetings | Simulation Meetings]] | <br><br> Return to [[Simulation_Meetings | Simulation Meetings]] | ||
<br> Return to [[Main_Page|Main Page]] | <br> Return to [[Main_Page|Main Page]] |
Revision as of 14:05, 19 March 2020
Back to Main Page >> Simulation Meetings
previous meeting << >> following meeting
Simulation Task List Updated 2019
- Simulation tasks (new)
File:MOLLER Tasks List v8 Sim.doc
Agenda
- Immediate simulation tasks to complete - Ciprian, Sakbi, Chandan
Attendance
Attendance: Chandan, Sakib, David Kashy, Dustin, Krishna, Ruben, Sandesh, Randy, Wouter
Minutes
- Chandan:
- test simulations on blocks of Pb with electrons, neutrons, gammas
- implementing beampipe drawings from Dave Kashy
- Sakib:
- sources of photon background from real shielding
- full geo, full geo - shower max shielding, full geo - shower max and shielding
- lead shielding causes 50 GHz of 1-10 MeV photon background
- showermax itself causes 40 GHz
- lead collars causes 80 GHz
- still looking for source of 100 GHz
- full geo, full geo - shower max shielding, full geo - shower max and shielding
- sources of photon background from real shielding
Return to Simulation Meetings
Return to Main Page