# Dump geometry location for SAMs Mark
 
# Dump geometry location for SAMs Mark
 
# Raster power supply box and radiation level Vassu  
 
# Raster power supply box and radiation level Vassu  
# Total ionization dose (TID) for DS torus: Zuhal
+
# Total ionization dose (TID) for DS torus: Zuhal; [https://moller.jlab.org/cgi-bin/DocDB/private/ShowDocument?docid=800]
 
# sim geometry for spectrometer enclosures and supports
 
# sim geometry for spectrometer enclosures and supports
 
# computing space at JLAB
 
# computing space at JLAB

Revision as of 16:04, 6 October 2021

Back to Main Page >> Simulation Meetings

previous meeting << >> following meeting

Simulation page


Agenda

  1. Dump geometry location for SAMs Mark
  2. Raster power supply box and radiation level Vassu
  3. Total ionization dose (TID) for DS torus: Zuhal; [1]
  4. sim geometry for spectrometer enclosures and supports
  5. computing space at JLAB

Attendance

Minutes

  1. SAM area background from the dump regions. Devi wants to look further into this, especially PMT for SAM to decide the shielding level. The develop is the branch that is the updated geometry for the dump. Ciprian and Vassu did the previous study.
  2. Raster power supply box and radiation level: Vassu
    1. Using a 3 cm thick stainless steel box seems adequate for total ionization dose (TID)
  3. Total ionization dose (TID) for DS torus: Zuhal
    1. This location (behind the lintels) exceeds TID for hall probes and may need a different solution
  4. Dave has a simplified Geometry for drift pipe, DS enclosure (clamps and lintels) for G4 to be loaded from engineering. Zuhal and Chandan will import drift pipe and DS enclosure. Julitte wants to make sure coils and clamps stay together in GDML for offset studies
    1. We will simplify most of the structural geometry before putting it into G4. We will also prioritize any materials with ferrous elements.
  5. Data storage and batch job issues encountered when running simulations in jlab farm: Ask Jim to increase guarantee storage size 25 TB

bluejeans information

Meeting ID 635010453


Meeting URL https://bluejeans.com/635010453


Here are more details about the meeting connection:


Connecting directly from a room system? 1) Dial: 199.48.152.152 or bjn.vc 2) Enter Meeting ID: 635 010 453

Just want to dial in on your phone? 1) +1.408.740.7256 (US)

   +1.888.240.2560 (US Toll Free)
   +1.408.317.9253 (Alternate number)

2) Enter Meeting ID: 635 010 453 3) Press #




Return to Simulation Meetings
Return to Simulations Main Page
Return to Main Page