Thursday, June 4, 2020 2pm ET

From Moller Wiki
Jump to: navigation, search

previous meeting << >> following meeting

 BlueJeans calling instructions:
 Toll-Free Number (U.S.&  Canada):  888-240-2560
 International toll number:         408-740-7256
 Bluejeans CODE:                    734 609 7559
 Bluejeans link: https://bluejeans.com/7346097559

Agenda

  • Coil down-select (est. Aug. 28, 2020)
    • Physics summary document
      • all simulations completed
    • Pugh matrix for eng. factors, cost and schedule
    • Change control board
      • review Ruben's recommendation
      • make a decision
  • Design and alignment tolerances
    • worst-case scenarios are tolerable
    • independent of the coil type (seg. vs. hyb.)
    • Recommendation should be closed - the method is developed
    • single coil offset studies still planned
  • Overall tolerance document (in progress)
    • some sims needed to clarify items in document
    • will present at a later meeting
  • Doses on coils/epoxy/braces
    • preliminary study done a couple years ago
    • repeated with updated exp. geometry
      • still rough (but conservative) on order of 100 MGy
  • Stray field study related recommendations
    • Develop a magnetic measurement plan
    • Evaluate need for full field map
    • Tolerances for alignment should include clean transport of beam
  • Magnet maximum current specification
    • Design vs. operational limit
    • design current is 20% above operating current for 11 GeV beam at nominal temperature
    • matters for specification of KPP (key performance parameters)
  • Other business
  • Next meeting



Thanks,

Minutes

Attendance: Ruben, Probir, Dave K., Dave F., Randy, Roger, KK, Chandan, Robin, Jay, Renuka, Sandesh, Juliette, Jim

  • Coil down-select (est. Aug. 28, 2020)
    • coil stresses
    • clearances
    • coil support design
    • coil adjustments
      • Q: Preserve capability as long as possible (max. degrees of freedom)
    • Local lead effects
    • clearances between coils and envelopes
  • Design and alignment tolerances
    • Physics (okay)
    • Doses
    • Clean transport of beam
    • Interference with the actual accepted envelopes
  • Overall tolerance document (in progress)
  • Doses on coils/epoxy/braces
  • Stray field study related recommendations
    • measure the field in the bore
      • what kind of tech is needed, how small of a field can we measure
      • rotating coil - a tube slightly smaller than the bore - instrumented at different radii
      • have a magnet measurement task group
      • probably no difference for the segmented vs. hybrid
      • g-2 pdf
  • Magnet maximum current specification
    • Design current 10% above operating current
    • threshold is 87% of 110% of design current (for 11 GeV)
    • student running sims
  • Other business
    • Envelopes (Chandan)
    • Test the simulations
  • Next meeting -



Return to Spectrometer Meetings