Thursday, June 4, 2020 2pm ET
From Moller Wiki
previous meeting << >> following meeting
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 408-740-7256 Bluejeans CODE: 734 609 7559 Bluejeans link: https://bluejeans.com/7346097559
Agenda
- Coil down-select (est. Aug. 28, 2020)
- Physics summary document
- all simulations completed
- Pugh matrix for eng. factors, cost and schedule
- Change control board
- review Ruben's recommendation
- make a decision
- Physics summary document
- Design and alignment tolerances
- worst-case scenarios are tolerable
- independent of the coil type (seg. vs. hyb.)
- Recommendation should be closed - the method is developed
- single coil offset studies still planned
- Overall tolerance document (in progress)
- some sims needed to clarify items in document
- will present at a later meeting
- Doses on coils/epoxy/braces
- preliminary study done a couple years ago
- repeated with updated exp. geometry
- still rough (but conservative) on order of 100 MGy
- Stray field study related recommendations
- Develop a magnetic measurement plan
- Evaluate need for full field map
- Tolerances for alignment should include clean transport of beam
- Magnet maximum current specification
- Design vs. operational limit
- design current is 20% above operating current for 11 GeV beam at nominal temperature
- matters for specification of KPP (key performance parameters)
- Other business
- Next meeting
Thanks,
Minutes
Attendance: Ruben, Probir, Dave K., Dave F., Randy, Roger, KK, Chandan, Robin, Jay, Renuka, Sandesh, Juliette, Jim
- Coil down-select (est. Aug. 28, 2020)
- coil stresses
- clearances
- coil support design
- coil adjustments
- Q: Preserve capability as long as possible (max. degrees of freedom)
- Local lead effects
- clearances between coils and envelopes
- Design and alignment tolerances
- Physics (okay)
- Doses
- Clean transport of beam
- Interference with the actual accepted envelopes
- Overall tolerance document (in progress)
- Doses on coils/epoxy/braces
- Stray field study related recommendations
- measure the field in the bore
- what kind of tech is needed, how small of a field can we measure
- rotating coil - a tube slightly smaller than the bore - instrumented at different radii
- have a magnet measurement task group
- probably no difference for the segmented vs. hybrid
- g-2 pdf
- measure the field in the bore
- Magnet maximum current specification
- Design current 10% above operating current
- threshold is 87% of 110% of design current (for 11 GeV)
- student running sims
- Other business
- Envelopes (Chandan)
- Test the simulations
- Next meeting -
Return to Spectrometer Meetings