+ | * Thoughts about getting ready for 90% review | ||
+ | ** Need to draft & submit the change request to take the VETROC out of design | ||
+ | ** HDMI cable length tests; decision on MPD position; radiation environment evaluation for MPDs | ||
+ | ** Availability of Hanjie's SOLID test stand firmware as reference/example for VTP trigger definition? | ||
+ | ** Follow-up with grounding working group? | ||
+ | ** Beam monitor requirements for counting mode and how to instrument? | ||
+ | ** Electrical safety evaluation of components; Electrical Safety Committee member for review? | ||
* General discussion | * General discussion | ||
== Minutes == | == Minutes == | ||
− | Recording on Zoom: | + | Recording on Zoom: [https://jlab-org.zoomgov.com/rec/share/AVAfwECKTexQE2qim6NEb7OyWxTWybnL9h3vrvtLzpzY12oan46lj7H2c5sHcuPs.qGuDyKst3bjfLj54?startTime=1650038371000] |
− | Participants: | + | Participants: C. Ghosh, R. Michaels, P. King, M. Gericke, D. McNulty, J. Fast |
+ | |||
+ | * Hanjie has started a new postdoc at BNL | ||
+ | ** ''Update after the meeting: Hanjie's VTP trigger design for the SOLID calorimeter is available at https://github.com/hanjie1/solid_ecal'' | ||
+ | * Bob reports on his test stand in TEDF | ||
+ | ** He's tested five SIS3820 scalers | ||
+ | ** He has FADC and VETROC in the crate; MOLLER won't use the VETROC but he is using this to also develop the polarimeter DAQs which will | ||
+ | ** He hasn't yet used the VTP trigger; he is following what is being done for the conversion to VTP triggering for the HCAL | ||
+ | * Discussion of HVMAPS | ||
+ | ** Michael plans to use a commercial FPGA that has a sufficient number of transceivers to connect to the HVMAPS | ||
+ | ** He has a test kit for the low-power transceivers from CERN | ||
+ | ** He will soon buy the FPGA | ||
+ | ** While he's at Mainz for the test beam, he'll have some time to talk with the engineer there who has been working with HVMAPS | ||
+ | * Paul asks if we could have ROCs that can be switched between integrating and counting mode; Bryan says that the TI modules can have two fiber inputs that can be selected during the CODA startup | ||
+ | * Jim brings up the issue of how Ohio will pay for the JLab designed modules | ||
+ | ** If all the effort is through the vendor PO, that would be easiest | ||
+ | ** If we need to pay JLab for some effort, it would require a CRADA | ||
+ | ** In the past there had been a way for universities to fund an account at the lab, but its not clear how that was actually handled | ||
+ | * Discussion about preparation for the 90% review | ||
+ | ** Jim is most concerned with the integration of the beamline instrumentation and the HVMAPS | ||
+ | *** Paul and Bob will set up a small group meeting with Yury, Mark P., and Kent to clarify our concerns/requirements, then we'll approach John M. again. |
Latest revision as of 15:47, 29 April 2022
Back to Main Page >> Data Acquisition Meetings >> Counting mode DAQ meetings
previous meeting << >> following meeting
Meeting information
Meeting time: 12:00pm Eastern Zoom connection information Join ZoomGov Meeting https://jlab-org.zoomgov.com/j/1603800887?pwd=aXVmSnN6aWZWN3RBdXB4RUhGckZJdz09 Meeting ID: 160 380 0887 Passcode: 903612 US Tool free phone: (833) 568 8864 Find your local number: https://jlab-org.zoomgov.com/u/ab8341cjcG
Agenda
- Activity updates
- Counting-mode DAQ prototype update
- Thoughts about getting ready for 90% review
- Need to draft & submit the change request to take the VETROC out of design
- HDMI cable length tests; decision on MPD position; radiation environment evaluation for MPDs
- Availability of Hanjie's SOLID test stand firmware as reference/example for VTP trigger definition?
- Follow-up with grounding working group?
- Beam monitor requirements for counting mode and how to instrument?
- Electrical safety evaluation of components; Electrical Safety Committee member for review?
- General discussion
Minutes
Recording on Zoom: [1]
Participants: C. Ghosh, R. Michaels, P. King, M. Gericke, D. McNulty, J. Fast
- Hanjie has started a new postdoc at BNL
- Update after the meeting: Hanjie's VTP trigger design for the SOLID calorimeter is available at https://github.com/hanjie1/solid_ecal
- Bob reports on his test stand in TEDF
- He's tested five SIS3820 scalers
- He has FADC and VETROC in the crate; MOLLER won't use the VETROC but he is using this to also develop the polarimeter DAQs which will
- He hasn't yet used the VTP trigger; he is following what is being done for the conversion to VTP triggering for the HCAL
- Discussion of HVMAPS
- Michael plans to use a commercial FPGA that has a sufficient number of transceivers to connect to the HVMAPS
- He has a test kit for the low-power transceivers from CERN
- He will soon buy the FPGA
- While he's at Mainz for the test beam, he'll have some time to talk with the engineer there who has been working with HVMAPS
- Paul asks if we could have ROCs that can be switched between integrating and counting mode; Bryan says that the TI modules can have two fiber inputs that can be selected during the CODA startup
- Jim brings up the issue of how Ohio will pay for the JLab designed modules
- If all the effort is through the vendor PO, that would be easiest
- If we need to pay JLab for some effort, it would require a CRADA
- In the past there had been a way for universities to fund an account at the lab, but its not clear how that was actually handled
- Discussion about preparation for the 90% review
- Jim is most concerned with the integration of the beamline instrumentation and the HVMAPS
- Paul and Bob will set up a small group meeting with Yury, Mark P., and Kent to clarify our concerns/requirements, then we'll approach John M. again.
- Jim is most concerned with the integration of the beamline instrumentation and the HVMAPS