Difference between revisions of "Simulation Meeting October 19 2023 11AM ET"
From Moller Wiki
(→Minutes) |
|||
(5 intermediate revisions by 2 users not shown) | |||
Line 6: | Line 6: | ||
=Agenda= | =Agenda= | ||
− | # Remoll Sensitive detector numbering in different | + | # FLUKA activation - dose near target region [https://moller.jlab.org/cgi-bin/DocDB/private/ShowDocument?docid=1173 docDB1173] |
− | + | # Remoll Sensitive detector numbering in different subsystems | |
− | + | # Pull Request protocol | |
− | + | # Resolve open issue list on remoll: Discuss next week | |
=Attendance= | =Attendance= | ||
=Minutes= | =Minutes= | ||
− | * | + | * FLUKA activation |
− | * | + | ** Using a partially closed Tungsten blocker at Col-1 will lower the radiation suffient for a day cool down access to some parts of the target area |
− | * | + | * Remoll Sensitive detector numbering in different sybsystems |
+ | ** Sakib may come up with a simple script to check already existing detector ids | ||
+ | ** In the meantime make sure to check remoll warnings for id duplication | ||
+ | ** Always turn ON detectors that required for the simulation | ||
+ | ** Check vertices and hit z locations on sensitive detector one would use in analysis to make sure they are coming from intended places and hitting the correct z location of the sensitive detector | ||
+ | * Pull Request protocol | ||
+ | ** When you submit a pull request make sure to assign a reviewer and then followup with an email to that person |
Latest revision as of 15:38, 19 October 2023
Back to Main Page >> Simulation Meetings
previous meeting << >> following meeting
Agenda
- FLUKA activation - dose near target region docDB1173
- Remoll Sensitive detector numbering in different subsystems
- Pull Request protocol
- Resolve open issue list on remoll: Discuss next week
Attendance
Minutes
- FLUKA activation
- Using a partially closed Tungsten blocker at Col-1 will lower the radiation suffient for a day cool down access to some parts of the target area
- Remoll Sensitive detector numbering in different sybsystems
- Sakib may come up with a simple script to check already existing detector ids
- In the meantime make sure to check remoll warnings for id duplication
- Always turn ON detectors that required for the simulation
- Check vertices and hit z locations on sensitive detector one would use in analysis to make sure they are coming from intended places and hitting the correct z location of the sensitive detector
- Pull Request protocol
- When you submit a pull request make sure to assign a reviewer and then followup with an email to that person