Difference between revisions of "Pion Meeting April 29 2022 3:30PM ET"

From Moller Wiki
Jump to: navigation, search
(Created page with "Back to Main Page >> Pion Meetings Zoom link: https://jlab-org.zoomgov.com/j/1608212513?pwd=M25LR1hzN3hLWm0xaFFETjZ0U1lQZz09 =Agenda= #Fai...")
 
(Minutes)
Line 13: Line 13:
  
 
=Minutes=
 
=Minutes=
 +
 +
* Elham: DAQ studies
 +
** blackening: demonstration of blackening, no more TIR on visual photo
 +
*** much lower energy peak with blackened sides, 5 channels vs 20 channels
 +
*** directionality is different from what will be orientation in MOLLER
 +
*** could put scintillator sideways, but at cost of lower rate
 +
** Juliette's Sr-90
 +
*** endpoint energy of 546 keV will range out in scintillator
 +
*** maybe get thinner scintillator for triggering

Revision as of 20:14, 29 April 2022

Back to Main Page >> Pion Meetings

Zoom link: https://jlab-org.zoomgov.com/j/1608212513?pwd=M25LR1hzN3hLWm0xaFFETjZ0U1lQZz09


Agenda

  1. Fair Sampling: open/closed/transition detectors - (David) [1]
  2. Update on prototyping the pion detector, blackening sides of the Acrylic- (Elham)(Elham)
  3. AOB

Attendance

Minutes

  • Elham: DAQ studies
    • blackening: demonstration of blackening, no more TIR on visual photo
      • much lower energy peak with blackened sides, 5 channels vs 20 channels
      • directionality is different from what will be orientation in MOLLER
      • could put scintillator sideways, but at cost of lower rate
    • Juliette's Sr-90
      • endpoint energy of 546 keV will range out in scintillator
      • maybe get thinner scintillator for triggering