Difference between revisions of "Pion Meeting June 25 2021 11AM ET"

From Moller Wiki
Jump to: navigation, search
(Attendance)
(Minutes)
 
Line 23: Line 23:
 
** What enters and exits the showermax?
 
** What enters and exits the showermax?
 
*** Picture of primaries leaving the showermax: the transition showermax detectors are where the primaries 'miss' the showermax
 
*** Picture of primaries leaving the showermax: the transition showermax detectors are where the primaries 'miss' the showermax
*** No pathological angles
+
*** No pathological angles between sectors
 +
*** Showermax should be staggered in r as well as z
 +
*** Same issue when changing donut concrete to lead
 +
** Are the particles hitting the back of the donut with angles less than 3.2 degree nominal angle?
 +
** Pion detector sees fair sample of pions, similar to what the showermax (and ring 5) sees
 +
** TODO:
 +
*** Stagger showermax in radius; tilt showermax by angle of 3.2 degrees
 +
*** Taper donut to shallower outer angle of 2.8 degrees
 +
*** Reduce phi acceptance of lucite, with pion rates as baseline
 
* Bayesian pion background correction (Julia, Elham)
 
* Bayesian pion background correction (Julia, Elham)
 +
**

Latest revision as of 19:23, 25 June 2021

Back to Main Page >> Pion Meetings

Agenda

  1. Updates on pion detector studies (Elham)
  2. Pion detector updates (David)
  3. Bayesian pion background correction (Julia, Elham)

Attendance

Elham, David, Julia, Jim, Sakib, Wouter

Minutes

  • Updates on pion detector studies (Elham)
    • Changed concrete donut to lead: decreases pions but no impact on electron background at low energies
      • Is more shielding bad? More hadronic interaction of pions, but not affected by shielding
    • Changed showermax lightguide to vacuum: increase rate of low energy electrons
  • Pion detector updates (David)
    • What enters and exits the showermax?
      • Picture of primaries leaving the showermax: the transition showermax detectors are where the primaries 'miss' the showermax
      • No pathological angles between sectors
      • Showermax should be staggered in r as well as z
      • Same issue when changing donut concrete to lead
    • Are the particles hitting the back of the donut with angles less than 3.2 degree nominal angle?
    • Pion detector sees fair sample of pions, similar to what the showermax (and ring 5) sees
    • TODO:
      • Stagger showermax in radius; tilt showermax by angle of 3.2 degrees
      • Taper donut to shallower outer angle of 2.8 degrees
      • Reduce phi acceptance of lucite, with pion rates as baseline
  • Bayesian pion background correction (Julia, Elham)