Difference between revisions of "Pion Meeting June 25 2021 11AM ET"
From Moller Wiki
(→Minutes) |
(→Minutes) |
||
(One intermediate revision by the same user not shown) | |||
Line 12: | Line 12: | ||
=Attendance= | =Attendance= | ||
− | Elham, David, Julia, Jim, Wouter | + | Elham, David, Julia, Jim, Sakib, Wouter |
=Minutes= | =Minutes= | ||
Line 23: | Line 23: | ||
** What enters and exits the showermax? | ** What enters and exits the showermax? | ||
*** Picture of primaries leaving the showermax: the transition showermax detectors are where the primaries 'miss' the showermax | *** Picture of primaries leaving the showermax: the transition showermax detectors are where the primaries 'miss' the showermax | ||
− | *** No pathological angles | + | *** No pathological angles between sectors |
+ | *** Showermax should be staggered in r as well as z | ||
+ | *** Same issue when changing donut concrete to lead | ||
+ | ** Are the particles hitting the back of the donut with angles less than 3.2 degree nominal angle? | ||
+ | ** Pion detector sees fair sample of pions, similar to what the showermax (and ring 5) sees | ||
+ | ** TODO: | ||
+ | *** Stagger showermax in radius; tilt showermax by angle of 3.2 degrees | ||
+ | *** Taper donut to shallower outer angle of 2.8 degrees | ||
+ | *** Reduce phi acceptance of lucite, with pion rates as baseline | ||
* Bayesian pion background correction (Julia, Elham) | * Bayesian pion background correction (Julia, Elham) | ||
+ | ** |
Latest revision as of 19:23, 25 June 2021
Back to Main Page >> Pion Meetings
- Bluejeans link: 420 107 252
- Dial-in: 408-740-7256 (US), 888-240-2560 (US Toll Free), 408-317-9253 (Alternate number)
Agenda
- Updates on pion detector studies (Elham)
- Pion detector updates (David)
- Bayesian pion background correction (Julia, Elham)
Attendance
Elham, David, Julia, Jim, Sakib, Wouter
Minutes
- Updates on pion detector studies (Elham)
- Changed concrete donut to lead: decreases pions but no impact on electron background at low energies
- Is more shielding bad? More hadronic interaction of pions, but not affected by shielding
- Changed showermax lightguide to vacuum: increase rate of low energy electrons
- Changed concrete donut to lead: decreases pions but no impact on electron background at low energies
- Pion detector updates (David)
- What enters and exits the showermax?
- Picture of primaries leaving the showermax: the transition showermax detectors are where the primaries 'miss' the showermax
- No pathological angles between sectors
- Showermax should be staggered in r as well as z
- Same issue when changing donut concrete to lead
- Are the particles hitting the back of the donut with angles less than 3.2 degree nominal angle?
- Pion detector sees fair sample of pions, similar to what the showermax (and ring 5) sees
- TODO:
- Stagger showermax in radius; tilt showermax by angle of 3.2 degrees
- Taper donut to shallower outer angle of 2.8 degrees
- Reduce phi acceptance of lucite, with pion rates as baseline
- What enters and exits the showermax?
- Bayesian pion background correction (Julia, Elham)