Difference between revisions of "Pion Meeting February 26 2021 11AM ET"

From Moller Wiki
Jump to: navigation, search
(Created page with "Back to Main Page >> Pion Meetings * Bluejeans link: [https://bluejeans.com/420107252 420 107 252] * Dial-in: [tel:408-740-7256p420107252# 4...")
 
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
  
 
=Agenda=
 
=Agenda=
# Different pion donut designs for the newgeometry with shielding in the electron and pion generator (Elham)
+
 
 +
# Different concrete/lead donut radius for the newgeometry with shielding in the electron and pion generator (Elham) [https://moller.jlab.org/cgi-bin/DocDB/private/ShowDocument?docid=694]
  
 
=Attendance=
 
=Attendance=
 +
 +
David, Elham, Raj, Wouter
  
 
=Minutes=
 
=Minutes=
 +
 +
* Local shielding of lucite detectors (downstream/inner radial) works better. This presentation: changing concrete/lead donut radius.
 +
* Rate of electrons goes down as radial size is increased: factor 10 decrease when increasing from 16 cm to 35 cm.
 +
* When changing the radial thickness of concrete and lead independently, the lead has a much larger impact.
 +
* When changing the longitudinal thickness of concrete and lead independently, the lead has a much larger impact as well.
 +
* Increasing both the radial thickness while reducing the longitudinal thickness does not result in a change (when keeping volume about the same).
 +
* Wouter working on visualization, will pass code to Elham.
 +
* Plan: make acrylic smaller in radial extent, keep inner radius the same, reduce outer radius, keep lightguide geometry identical

Latest revision as of 16:58, 26 February 2021

Back to Main Page >> Pion Meetings

Agenda

  1. Different concrete/lead donut radius for the newgeometry with shielding in the electron and pion generator (Elham) [1]

Attendance

David, Elham, Raj, Wouter

Minutes

  • Local shielding of lucite detectors (downstream/inner radial) works better. This presentation: changing concrete/lead donut radius.
  • Rate of electrons goes down as radial size is increased: factor 10 decrease when increasing from 16 cm to 35 cm.
  • When changing the radial thickness of concrete and lead independently, the lead has a much larger impact.
  • When changing the longitudinal thickness of concrete and lead independently, the lead has a much larger impact as well.
  • Increasing both the radial thickness while reducing the longitudinal thickness does not result in a change (when keeping volume about the same).
  • Wouter working on visualization, will pass code to Elham.
  • Plan: make acrylic smaller in radial extent, keep inner radius the same, reduce outer radius, keep lightguide geometry identical