Difference between revisions of "Pion Meeting February 26 2021 11AM ET"
From Moller Wiki
(Created page with "Back to Main Page >> Pion Meetings * Bluejeans link: [https://bluejeans.com/420107252 420 107 252] * Dial-in: [tel:408-740-7256p420107252# 4...") |
|||
(One intermediate revision by the same user not shown) | |||
Line 5: | Line 5: | ||
=Agenda= | =Agenda= | ||
− | # Different | + | |
+ | # Different concrete/lead donut radius for the newgeometry with shielding in the electron and pion generator (Elham) [https://moller.jlab.org/cgi-bin/DocDB/private/ShowDocument?docid=694] | ||
=Attendance= | =Attendance= | ||
+ | |||
+ | David, Elham, Raj, Wouter | ||
=Minutes= | =Minutes= | ||
+ | |||
+ | * Local shielding of lucite detectors (downstream/inner radial) works better. This presentation: changing concrete/lead donut radius. | ||
+ | * Rate of electrons goes down as radial size is increased: factor 10 decrease when increasing from 16 cm to 35 cm. | ||
+ | * When changing the radial thickness of concrete and lead independently, the lead has a much larger impact. | ||
+ | * When changing the longitudinal thickness of concrete and lead independently, the lead has a much larger impact as well. | ||
+ | * Increasing both the radial thickness while reducing the longitudinal thickness does not result in a change (when keeping volume about the same). | ||
+ | * Wouter working on visualization, will pass code to Elham. | ||
+ | * Plan: make acrylic smaller in radial extent, keep inner radius the same, reduce outer radius, keep lightguide geometry identical |
Latest revision as of 16:58, 26 February 2021
Back to Main Page >> Pion Meetings
- Bluejeans link: 420 107 252
- Dial-in: 408-740-7256 (US), 888-240-2560 (US Toll Free), 408-317-9253 (Alternate number)
Agenda
- Different concrete/lead donut radius for the newgeometry with shielding in the electron and pion generator (Elham) [1]
Attendance
David, Elham, Raj, Wouter
Minutes
- Local shielding of lucite detectors (downstream/inner radial) works better. This presentation: changing concrete/lead donut radius.
- Rate of electrons goes down as radial size is increased: factor 10 decrease when increasing from 16 cm to 35 cm.
- When changing the radial thickness of concrete and lead independently, the lead has a much larger impact.
- When changing the longitudinal thickness of concrete and lead independently, the lead has a much larger impact as well.
- Increasing both the radial thickness while reducing the longitudinal thickness does not result in a change (when keeping volume about the same).
- Wouter working on visualization, will pass code to Elham.
- Plan: make acrylic smaller in radial extent, keep inner radius the same, reduce outer radius, keep lightguide geometry identical