Difference between revisions of "Pion Meeting February 12 2021 11AM ET"

From Moller Wiki
Jump to: navigation, search
(Created page with "Back to Main Page >> Pion Meetings * Bluejeans link: [https://bluejeans.com/420107252 420 107 252] * Dial-in: [tel:408-740-7256p420107252# 4...")
 
(Minutes)
Line 12: Line 12:
  
 
=Minutes=
 
=Minutes=
 +
 +
New design evaluation:
 +
* lucite tilted at 22.5 deg
 +
* lucite tilted at 45 deg
 +
* larger lead donut outer radius
 +
 +
Increase in pion rate when adding 10 cm lead: probably scattering of larger radius pions into the lucite when they otherwise would have just hit the hall wall
 +
 +
The rate for the Moller generator with > 2 MeV goes up when the lucite is tilted: lucite covers more solid angle for a shower on the outer downstream radial edge of the lead donut. But why does that corner light up?
 +
 +
Q: We should determine the dependence of the pi/e ratios on the radial lead donut extent from 16 cm to larger than 26 cm.
 +
 +
Q: We should run with a lucite with 5 cm height.
 +
 +
Q: Run visualization for Moller generator events that cause light to reach the pion detector PMT.
 +
 +
Q: How important is the ep tail for this larger lead donut radial extent?
 +
 +
Q: Can we extend only the concrete in radius, not the lead? Can we make the lead thinner if we make it further in radius?
 +
 +
Studies:
 +
* concrete/lead radius extend 16, 21, 26, 30, 35 cm
 +
* keep concrete at 16 cm, extend lead only to 26 cm
 +
* keep lead at 16 cm, extend concrete only to 26 cm
 +
* fix downstream face of donut, then reduce lead thickness

Revision as of 16:54, 12 February 2021

Back to Main Page >> Pion Meetings

Agenda

  1. Different designs for the newgeometry with shielding in the electron and pion generator (Elham) [1]

Attendance

Elham, Wouter, David, Jim

Minutes

New design evaluation:

  • lucite tilted at 22.5 deg
  • lucite tilted at 45 deg
  • larger lead donut outer radius

Increase in pion rate when adding 10 cm lead: probably scattering of larger radius pions into the lucite when they otherwise would have just hit the hall wall

The rate for the Moller generator with > 2 MeV goes up when the lucite is tilted: lucite covers more solid angle for a shower on the outer downstream radial edge of the lead donut. But why does that corner light up?

Q: We should determine the dependence of the pi/e ratios on the radial lead donut extent from 16 cm to larger than 26 cm.

Q: We should run with a lucite with 5 cm height.

Q: Run visualization for Moller generator events that cause light to reach the pion detector PMT.

Q: How important is the ep tail for this larger lead donut radial extent?

Q: Can we extend only the concrete in radius, not the lead? Can we make the lead thinner if we make it further in radius?

Studies:

  • concrete/lead radius extend 16, 21, 26, 30, 35 cm
  • keep concrete at 16 cm, extend lead only to 26 cm
  • keep lead at 16 cm, extend concrete only to 26 cm
  • fix downstream face of donut, then reduce lead thickness