Difference between revisions of "Digital BCM Meeting, 2021 January 07"
From Moller Wiki
(→Agenda) |
m |
||
(6 intermediate revisions by 2 users not shown) | |||
Line 2: | Line 2: | ||
Back to [[Main_Page|Main Page]] >> [[DAQ Meetings|Data Acquisition Meetings]] | Back to [[Main_Page|Main Page]] >> [[DAQ Meetings|Data Acquisition Meetings]] | ||
+ | [[Digital BCM Meeting, 2021 January 07|previous meeting]] << >> [[Digital BCM Meeting, 2021 January 21|next meeting]] | ||
== Meeting information == | == Meeting information == | ||
Line 14: | Line 15: | ||
== Agenda == | == Agenda == | ||
− | * Control signal inputs | + | * Control signal inputs: integrate gate or "start of integration"? |
* Possible readout ideas | * Possible readout ideas | ||
** Each unit as stand-alone ROC similar to integrating ADCs | ** Each unit as stand-alone ROC similar to integrating ADCs | ||
Line 22: | Line 23: | ||
** Integrating ADCs plan to have: sum over window, sum of squares (to calculate RMS within window), minimum sample value, maximum sample value; full window and four sub-blocks. Integrating ADCs would also have a waveform mode. | ** Integrating ADCs plan to have: sum over window, sum of squares (to calculate RMS within window), minimum sample value, maximum sample value; full window and four sub-blocks. Integrating ADCs would also have a waveform mode. | ||
* General discussion | * General discussion | ||
+ | * [https://moller.jlab.org/wiki/index.php/File:LBL_BCM_datastream(1).pdf LBL BCM data structure] | ||
+ | |||
+ | == Minutes == | ||
+ | Attendees: Paul, Bob, Yuan, Yury, Ernst, Shujie | ||
+ | |||
+ | * Experiment requirements: | ||
+ | ** BCM info to integrating mode and counting mode DAQ | ||
+ | ** BPM info at low current (100 pA) for counting mode | ||
+ | |||
+ | * Proposed setup: | ||
+ | ** Integrate the BCM/server system to main CODA | ||
+ | ** Ideally, the FPGA on BCM will process the raw cavity signal (output at ~2kHz) and communicate with CODA ('''TODO: check with Bryan from DAQ group if both the ROC and TI can be implemented in the FPGA, or do we need a Unix shell for the ROC''' ) so that we can drop the server to increase system stability. | ||
+ | ** Helicity window signal (500us on, 10us off) to BCM. | ||
+ | *** is the helicity signal in sync with 10MHz clock? (very likely yes) | ||
+ | *** how to define the rising edge of helicity window (~50ns ??) | ||
+ | *** need to sync the helicity with BCM input signal. Use the LED delta signal to check sync? |
Latest revision as of 20:24, 20 January 2021
Back to Main Page >> Data Acquisition Meetings
previous meeting << >> next meeting
Meeting information
Meeting time: 2:00pm Eastern BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 Other BlueJeans access phone numbers are listed at https://www.bluejeans.com/premium-numbers Bluejeans CODE: 641 252 323 Bluejeans link: https://bluejeans.com/641252323
Agenda
- Control signal inputs: integrate gate or "start of integration"?
- Possible readout ideas
- Each unit as stand-alone ROC similar to integrating ADCs
- Units are read by a computer with TI-pcie running a PC-ROC
- Units communicate with a VXS module (such as SSP) in a VXS-ROC
- Data structure; what is reported?
- Integrating ADCs plan to have: sum over window, sum of squares (to calculate RMS within window), minimum sample value, maximum sample value; full window and four sub-blocks. Integrating ADCs would also have a waveform mode.
- General discussion
- LBL BCM data structure
Minutes
Attendees: Paul, Bob, Yuan, Yury, Ernst, Shujie
- Experiment requirements:
- BCM info to integrating mode and counting mode DAQ
- BPM info at low current (100 pA) for counting mode
- Proposed setup:
- Integrate the BCM/server system to main CODA
- Ideally, the FPGA on BCM will process the raw cavity signal (output at ~2kHz) and communicate with CODA (TODO: check with Bryan from DAQ group if both the ROC and TI can be implemented in the FPGA, or do we need a Unix shell for the ROC ) so that we can drop the server to increase system stability.
- Helicity window signal (500us on, 10us off) to BCM.
- is the helicity signal in sync with 10MHz clock? (very likely yes)
- how to define the rising edge of helicity window (~50ns ??)
- need to sync the helicity with BCM input signal. Use the LED delta signal to check sync?