Difference between revisions of "Target Region Shielding"
From Moller Wiki
(→Tasks) |
|||
Line 28: | Line 28: | ||
** [https://www.nelcoworldwide.com/medical-shielding-products/concrete/high-density-concrete-block/ NelcoHDcrete] | ** [https://www.nelcoworldwide.com/medical-shielding-products/concrete/high-density-concrete-block/ NelcoHDcrete] | ||
** concrete with galena aggregate [https://moller.jlab.org/cgi-bin/DocDB/private/ShowDocument?docid=643 docDBlink] | ** concrete with galena aggregate [https://moller.jlab.org/cgi-bin/DocDB/private/ShowDocument?docid=643 docDBlink] | ||
+ | ** '''If these don't contain a Barite mix we should look for one to include in our studies''' | ||
* Re-run analysis for new materials and summarize findings | * Re-run analysis for new materials and summarize findings | ||
Line 34: | Line 35: | ||
* between target and 1st Pb wall | * between target and 1st Pb wall | ||
* plane right US of Hybrid (will make kryptonite for these simulations) | * plane right US of Hybrid (will make kryptonite for these simulations) | ||
+ | * detectors will be placed in the parallel world |
Revision as of 17:01, 16 September 2020
Meetings
Tasks
Task Title | Task Short Description | Responsible | DocDB link |
---|---|---|---|
Material analysis | Description | Chandan | To be added |
Needed detectors | Define detectors needed for simulation | Ciprian | To be added |
Geometry implementation | Develop plan to efficiently implement changes | Open slot | To be added |
Run simulations | Running either on compute canada or ifarm | Open slot | To be added |
1st pass analysis | Flesh out analysis scripts and get base level of radiation | Open slot | To be added |
Descriptions
Material analysis
- Document current analysis (look back at PREX analysis by Caryn and MOLLER analysis by Chandan)
- List of materials:
- DenseCrete 5.21 g/cc (has Fe oxides - may not want near beamline) denseCrete
- RadCrete
- PittHDcrete
- NelcoHDcrete
- concrete with galena aggregate docDBlink
- If these don't contain a Barite mix we should look for one to include in our studies
- Re-run analysis for new materials and summarize findings
Needed detectors
- US of target: Moller polarimeter, Compton, Front of SBS bunker
- between target and 1st Pb wall
- plane right US of Hybrid (will make kryptonite for these simulations)
- detectors will be placed in the parallel world