Wednesday, May 8, 2019 2pm ET

From Moller Wiki
Jump to: navigation, search

previous meeting << >> following meeting

Logistic information

 BlueJeans calling instructions:
 Toll-Free Number (U.S.&  Canada):  888-240-2560
 International toll number:         408-740-7256
 Bluejeans CODE:                    734 609 7559
 Bluejeans link: https://bluejeans.com/7346097559

Agenda

  • Beam Pipe Design pdf, xls
  • Design Questions Document pdf, xls


Minutes

Attendance: Juliette, KK, Ruben, Dave, Probir

  • Beam Pipe Design
    • numbers from Chandan checked - need updating
    • upstream torus angle a little different
    • guaranteed scraping with 1.77 mm only barely enough to fit pipe with no clearance
    • collimator 1 needs to shrink with the new geometry
      • probably better to shrink collimator than to decrease the raster size
      • modify upstream torus to give constant clearance (1.77 mm clearance to 9.28 mm clearance)
      • What else to try first
        • 5 sigma for 1.25 m (15 -> 13 mm)
        • Our total power is less (85 - 70 uA)
  • Design Questions Document



Return to Spectrometer Meetings