Difference between revisions of "Simulation Meeting March 11 2021 2PM ET"
From Moller Wiki
Line 1: | Line 1: | ||
Back to [[Main_Page|Main Page]] >> [[Simulation_Meetings | Simulation Meetings]] | Back to [[Main_Page|Main Page]] >> [[Simulation_Meetings | Simulation Meetings]] | ||
− | [[Simulation_Meeting_March_4_2021_2PM_ET | previous meeting]] << >> [[ | + | [[Simulation_Meeting_March_4_2021_2PM_ET | previous meeting]] << >> [[Simulation_Meeting_March_18_2021_2PM_ET | following meeting]] |
[[Simulations | Simulation page ]] | [[Simulations | Simulation page ]] | ||
Line 7: | Line 7: | ||
=Agenda= | =Agenda= | ||
− | |||
# Al generator issues: Hanjie and Ciprian [https://github.com/JeffersonLab/remoll/issues/443 githubIssue443] | # Al generator issues: Hanjie and Ciprian [https://github.com/JeffersonLab/remoll/issues/443 githubIssue443] | ||
#* the generator for both the [https://github.com/JeffersonLab/remoll/blob/master/src/remollGenAl.cc#L201 quasiElastic] and [https://github.com/JeffersonLab/remoll/blob/master/src/remollGenAl.cc#L152 inelastic] generators have a beam-Energy factor in the x-section | #* the generator for both the [https://github.com/JeffersonLab/remoll/blob/master/src/remollGenAl.cc#L201 quasiElastic] and [https://github.com/JeffersonLab/remoll/blob/master/src/remollGenAl.cc#L152 inelastic] generators have a beam-Energy factor in the x-section | ||
Line 16: | Line 15: | ||
=Minutes= | =Minutes= | ||
− | # | + | # Target shielding update by Zuhal |
+ | ## Compared 4 configurations using different sensitive detectors | ||
+ | ## We are getting close to a final design so target group can start on engineering plans for the final simulation design. | ||
+ | ## We have to complete the site boundary dose estimation with out current design | ||
+ | #Al Generator update | ||
+ | ## Hanjie wanted to know an MC factor in the Al generator code is correct. That is a normalization factor for MC simulation event generator. | ||
+ | |||
=bluejeans information= | =bluejeans information= |
Revision as of 20:04, 11 March 2021
Back to Main Page >> Simulation Meetings
previous meeting << >> following meeting
Contents
[hide]Agenda
- Al generator issues: Hanjie and Ciprian githubIssue443
- the generator for both the quasiElastic and inelastic generators have a beam-Energy factor in the x-section
- confirmed this was in the original Qweak generators, but not clear why it is there. The original ref eq3 doesn't have this
Attendance
Minutes
- Target shielding update by Zuhal
- Compared 4 configurations using different sensitive detectors
- We are getting close to a final design so target group can start on engineering plans for the final simulation design.
- We have to complete the site boundary dose estimation with out current design
- Al Generator update
- Hanjie wanted to know an MC factor in the Al generator code is correct. That is a normalization factor for MC simulation event generator.
bluejeans information
Meeting ID 635010453
Meeting URL
https://bluejeans.com/635010453
Here are more details about the meeting connection:
Connecting directly from a room system? 1) Dial: 199.48.152.152 or bjn.vc 2) Enter Meeting ID: 635 010 453
Just want to dial in on your phone? 1) +1.408.740.7256 (US)
+1.888.240.2560 (US Toll Free) +1.408.317.9253 (Alternate number)
2) Enter Meeting ID: 635 010 453 3) Press #
Return to Simulation Meetings
Return to Simulations Main Page
Return to Main Page